Heatshrink

Thin Wall

ATW

Technical Data

Properties Test Methods Typical Values
Tensile (MPa) UL 224 > 10.4
Elongation (%) UL 224 > 200
Heat Ageing: Tensile (MPa)
 lllllllllllllllllllll: Elongation (%)
UL 224 (158°C x 168 hrs)
s
> 7.3
> 100
Heat Shock UL 224 (250°C x 4hrs) No Cracks/Dripping
Low temperature Flexibility ASTM D 2671 (4 hrs @ – 35°C ) No Cracking
Copper Stability ASTM D 2671 (158°C x 168 hrs) Pass
RoHS (ppm) IEC 62321 (Cd, Pb, Cr6, Hg) < 200
Flammability  VW-1 Pass
Dielectric Strength (kV/mm) ASTM D 2671 > 15
Volume Resistivity ASTM D 257
Halogen Test (ppm) EN 114582 (BF, Ci, Fl, I) < 800

Description

ATW is a halogen free, RoHS, flame retardant tubing designed for application in closed and sensitive environments such as trains, ships and in underground mining where the formation of acid gas after fire must be minimised to avoid consequential damage to computers, PC’s and electronic control equipment. Being RoHS compliant means the product does not contain restricted substances such as Cadmium (Cd), Lead (Pb), Hexavalent Chrome (Cr6) and Mercury (Hg). RoHS is now a requirement in the automotive industry.

 

Features

  • Cross-linked polyolefin
  • Shrink Ratio 2 : 1
  • Operating temperature – 55 to 125°C
  • Excellent flame retardance VW-1
  • Colours – Standard colours, green/ yellow stripe and clear
  • Minimum shrink temperature 70°C
  • 600V
  • Black – UV Stable

Applications

  • Quick recovery at low temperatures makes it ideal for use in electronics and telecommunication applications
  • RoHS coupled to flame retardant properties makes this product suitable for use in automotive harnesses
  • Ships, trains and underground mining
  • Any enclosed areas which contain sensitive electronic equipment and computers

 

 Other Colours on request

Inside Diameter vs Layflat

Dimensions

Product Inside Diameter (mm) Lay-flat size (mm)

Suitable for wire sizes

(mm²)

Wall Thickness (mm)

Length per reël

(m)

Supplied Recovered Supplied Recovered
ATW1.2 1.2 0.6 2 0.18 0.36 200
ATW1.6 1.6 0.8 2.5 0.18 0.36 200
ATW2.4 2.4 1.2 3.8 0.5 0.18 0.36 200
ATW3.2 3.2 1.6 5 1 0.20 0.40 200
ATW4.8 4.8 2.4 7.5 1.5-2.5 0.23 0.46 100
ATW6.4 6.4 3.2 10 4-6 0.28 0.60 100
ATW9.5 9.5 4.8 15 10-16 0.30 0.60 100
ATW12.7 12.7 6.4 20 25-35 0.33 0.66 100
ATW16 16.0 8 25 0.38 0.76 100
ATW19 19.0 9.5 30 50-95 0.40 0.80 100
ATW25.4 25.4 12.7 40 120-185 0.45 0.90 50
ATW32 32.0 16 50 0.45 0.90 50
ATW38.1 38.1 19 60 240-300 0.50 1.00 50
ATW50.8 50.8 25.4 80 500-630 0.50 1.00 25
ATW76 76.0 38 120 0.65 1.30 25
ATW100 100.0 50.8 160 0.65 1.30 25

Tolerances for recovered wall thickness from 1.6 to 16 mm + – 0.10 mm
                                                                                  19 to 50 mm + – 0.15 mm
                                                                                  50 to 100 mm + – 0.2 mm

Tel: 011 868 3783 • Fax: 011 868 3773
E-mail: office@airshrinksa.co.za
www.airshrinksa.co.za

8

Heatshrink

Thin Wall Flexible

ATWF

 

Technical Data

Properties Test Methods Typical Values
Tensile (MPa) UL 224 > 15
Elongation (%) UL 224 > 300
Heat Ageing: Tensile (MPa)
 lllllllllllllllllllll: Elongation (%)
UL 224
(158°C x 168 hrs)
> 12
> 250
Heat Shock (250°C x 4hrs) UL 224 Pass
Low temperature
Flexibility
ASTM D 2671
(4 hrs @ – 35°C)
No Cracks / Pass
s
Fluid Resistance * (MPa)
llllllllllllllllllllllllllllllllr(%)
ASTM D 2671
(25°C x 72 hrs)
Tensile > 7.8
Elongation > 150
Dielectric Strength (kV/mm) ASTM D 2671 > 20
Volume Resistivity (Ω.cm) ASTM D 257 1014

*Fluid Resistance: Tests conducted using brake fluid and unleaded petrol

Description

ATWF is a non flame retardant flexible heatshrink tubing which has excellent oil resistance. It forms an attractive covering for many automotive, appliance, and consumer-good applications. ATWF is RoHS and Halogen Free.

 

Features

  • Shrink Ratio 2 : 1
  • Operating temperature – 35 to 125°C
  • High chemical resistance
  • Good abrasion resistance
  • Colours – Standard colours
  • Minimum shrink temperature 115°C

Applications

  • Insulation and colour coding of busbars and lugs.
  • Insulation and strain relief of electronic connections and terminations
  • Cable bundling
  • Mechanical protection and aesthetic covering for consumer goods

Dimensions

Product

Inside Diameter (mm) Wall Thickness (mm)
Supplied Recovered Supplied Recovered
ATWF2.4 2.4 1.2 0.25 0.50
ATWF3.2 3.2 1.6 0.25 0.50
ATWF4.8 4.8 2.4 0.25 0.50
ATWF6.4 6.4 3.2 0.25 0.60
ATWF9.5 9.5 4.8 0.35 0.60
ATWF12.7 12.7 6.4 0.35 0.60
ATWF16 16 8 0.40 0.75
ATWF19 19 9.5 0.40 0.75
ATWF25.4 25.4 12.7 0.50 0.90
ATWF32 32 16 0.50 1.10
ATWF38.1 38.1 19.1 0.60 1.20
ATWF50.8 50.8 25.4 0.70

1.50

Eccentricity < 30% as per UL 224
Tolerances on size id’s and wall thickness allow 15% on above values

Tel: 011 868 3783 • Fax: 011 868 3773
E-mail: office@airshrinksa.co.za
www.airshrinksa.co.za

9

Heatshrink

Thin Wall Clear

ATWC

s

Technical Data

Properties Test Methods Typical Values
Tensile (MPa) UL 224 > 15
Elongation (%) UL 224 > 300
Heat Ageing: Tensile (MPa)
 lllllllllllllllllllll: Elongation (%)
UL 224
(158°C x 168hrs)
> 12
> 250
Heat Shock (250°C x 4hrs) UL 224 Pass
Low temperature Flexibility
s
ASTM D 2671
(4 hrs @ – 35°C)
No Cracks / Pass
s
Fluid Resistance * (MPa) ASTM D 2671 Tensile > 10
Dielectric Strength (kV/mm) ASTM D 2671 > 20
Volume Resistivity (Ω.cm) ASTM D 257 1014

*Fluid Resistance: Tests conducted using brake fluid and unleaded petrol

Description

ATWC is a non flame retardant clear tubing which has excellent oil resistance and clarity. ATWC is RoHS and halogen free.

 

Features

  • Shrink Ratio 2 : 1
  • Operating temperature – 55 to 125°C
  • High chemical resistance
  • Good abrasion resistance
  • Excellent oil resistance
  • Minimum shrink temperature 115°C

Applications

  • Oil barrier in paper cable joints
  • Abrasion and oil resistant covering for heatshrink and write and wrap labels
  • Clear retainer for shock absorbers on safety harnesses
  • Strain relief for electrical and electronic connections where visibility of connection is required

Dimensions

Product

Inside Diameter (mm) Wall Thickness (mm)
Supplied Recovered Supplied Recovered
ATWC1.2 1.2 0.6 0.18 0.36
ATWC1.6 1.6 0.8 0.18 0.36
ATWC2.4 2.4 1.2 0.18 0.36
ATWC3.2 3.2 1.6 0.20 0.40
ATWC4.8 4.8 2.4 0.23 0.46
ATWC6.4 6.4 3.2 0.28 0.60
ATWC9.5 9.5 4.8 0.30 0.60
ATWC12.7 12.7 6.4 0.33 0.66
ATWC16 16 8.0 0.38 0.76
ATWC19 19 9.5 0.40 0.80
ATWC25.4 25.4 12.7 0.45 0.90
ATWC32 32 16 0.45 0.90
ATWC38.1 38.1 19.1 0.50 1.0
ATWC50.8 50.8 25.4 0.50 1.0
ATWC76 76 38 0.65

1.30

Tolerances for recovered wall thickness from 1.6 to 16 mm +- 0.10 mm
                                                                                  19 to 50 mm +- 0.15 mm
                                                                                  50 to 100 mm +- 0.2 mm

Tel: 011 868 3783 • Fax: 011 868 3773
E-mail: office@airshrinksa.co.za
www.airshrinksa.co.za